NSN (5915001035766) – NSN 5915-00-103-5766 Parts List

Item Name Filter Radio Frequency Interfere
Federal Supply Group (FSG) Electrical and Electronic Equipment Components
Federal Supply Class (FSC) 5915 Filters and Networks
National Item Identification Number (NIIN) 00-103-5766 (001035766)
NCB Code USA (00)
Manufacturer Ems Development Corporation, Lindgren Edmund Co, Mtk Electronics Inc, Gauss Control Inc
Part Number Manufacturer Item Name Cage Code RFQ
RF4455 ems development corporation filter radio frequency interfere 13619 RFQ
E-1841 lindgren edmund co filter radio frequency interfere 23160 RFQ
M1547 mtk electronics inc filter radio frequency interfere 59901 RFQ
G87219 gauss control inc filter radio frequency interfere 1f702 RFQ
RF04455 ems development corporation filter radio frequency interfere 13619 RFQ

Technical Characteristics of NSN 5915001035766

MRCCriteriaCharacteristic
ABHPOVERALL LENGTH11.250 INCHES NOMINAL
ABKWOVERALL HEIGHT7.850 INCHES NOMINAL
ADAQBODY LENGTH10.000 INCHES NOMINAL
ADATBODY WIDTH2.470 INCHES NOMINAL
ADAUBODY HEIGHT5.970 INCHES NOMINAL
AFGAOPERATING TEMP RANGE-45.0 TO 71.0 DEG CELSIUS
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS30.0 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS30.0 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS30.0 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS30.0 4TH RADIO INTERFERENCE 4TH FUNCTION
AKNAINCLOSURE TYPEENCASED
AXHRMOUNTING FACILITY TYPE AND QUANTITY1 THREADED STUD 1ST FUNCTION
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY4 THREADED STUD INPUT 1ST FUNCTION
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY4 THREADED STUD OUTPUT 2ND FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION130.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION130.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION130.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION130.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION
CRDCMAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE800.0 VOLTS AT SEA LEVEL
STYLSTYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
TESTTEST DATA DOCUMENT18876-11071911 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA

Relevant Components for NSN - 5915-00-103-5766, 5915001035766
5930-01-525-6743 (5930015256743) 5905-00-112-5274 (5905001125274) 5962-01-367-6024 (5962013676024) 5975-00-280-9809 (5975002809809)
5962-01-668-1209 (5962016681209) 5995-01-429-6663 (5995014296663) 5945-00-259-0525 (5945002590525) 5999-01-201-4414 (5999012014414)
5985-01-312-4125 (5985013124125) 5962-01-295-0963 (5962012950963) 5935-01-408-8097 (5935014088097) 5998-01-408-9093 (5998014089093)

Submit a Quote and We'll Get Back to You Shortly

Guaranteed quotes back within 15 minutes, 24/7 x 365

Thank You for Visiting.

If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.

Request for Quote

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.

bottom to top