MRC | Criteria | Characteristic |
---|
ABKW | OVERALL HEIGHT | 4.660 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 2.030 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.030 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 2.530 INCHES MAXIMUM |
AECR | VIBRATION RESISTANCE RANGE IN HERTZ | 10.0 TO 500.0 |
AFGA | OPERATING TEMP RANGE | -28.0 TO 65.0 DEG CELSIUS |
AFSV | AVERAGE LIFE RATING IN HOURS | 20000.0 |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 1ST RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 2ND RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 4TH RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 2ND RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.15 VOLTS AC 4TH RADIO INTERFERENCE |
AHBN | INPUT TERMINAL MANUFACTURER CODE | 71468 |
AHBP | INPUT TERMINAL IDENTIFICATION | BFH-20-4P-002 |
AHCG | MAXIMUM TEMP RISE | 25.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | ENCASED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 TERMINAL |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR,RECEPTACLE INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 4 THREADED STUD OUTPUT 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION |
CQRG | BODY MATERIAL | METAL |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |