Item Name Filter Radio Frequency Interfere
Federal Supply Group (FSG) Electrical and Electronic Equipment Components
Federal Supply Class (FSC) 5915 Filters and Networks
National Item Identification Number (NIIN) 01-339-6647 (013396647)
NCB Code USA (01)
Manufacturer Ems Development Corporation, Litton Systems Inc, Greatbatch Sierra Inc, Avx Filters Corp
Part Number Manufacturer Item Name Cage Code RFQ
RF15667 ems development corporation filter radio frequency interfere 13619 RFQ
841795-01 litton systems inc filter radio frequency interfere 13973 RFQ
9922S50-2XA greatbatch sierra inc filter radio frequency interfere 79474 RFQ
841795-1 litton systems inc filter radio frequency interfere 13973 RFQ
PZ9CZ-M00A avx filters corp filter radio frequency interfere 59942 RFQ

Technical Characteristics of NSN 5915013396647

MRCCriteriaCharacteristic
ABHPOVERALL LENGTH5.700 INCHES MAXIMUM
ADAUBODY HEIGHT2.000 INCHES MAXIMUM
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH4.320 INCHES NOMINAL
AGAVEND ITEM IDENTIFICATIONTACTICAL AIR OPERATIONS MODULE AN/TYQ-23(V)1
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS0.1 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION0.5 VOLTS AC 3RD RADIO INTERFERENCE AND 0.05 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION0.5 VOLTS AC 6TH RADIO INTERFERENCE AND 0.1 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE 5TH FUNCTION
AHBNINPUT TERMINAL MANUFACTURER CODE13973
AHBSOUTPUT TERMINAL MANUFACTURER CODE13973
AHCJFULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ0.0 AND 0.1 AND 1.0 AND 10.0 AND 100.0 AND 1000.0
CQDZMAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE125.0 VOLTS AT SEA LEVEL
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION50.0 VOLTS AC 2ND RADIO INTERFERENCE AND 50.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION50.0 VOLTS AC 4TH RADIO INTERFERENCE AND 50.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION50.0 VOLTS AC 6TH RADIO INTERFERENCE AND 50.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION
CRDCMAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE125.0 VOLTS AT SEA LEVEL
CTJSUNPACKAGED UNIT WEIGHT4.410 POUNDS NOMINAL
STYLSTYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON TWO SURFACES
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS0.1 3RD RADIO INTERFERENCE 3RD FUNCTION
AHCGMAXIMUM TEMP RISE25.0 DEG CELSIUS
AHCKFULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS3.0 AND 10.0 AND 40.0 AND 60.0 AND 70.0 AND 90.0
AKEJMOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNF
AXHRMOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION50.0 VOLTS AC 1ST RADIO INTERFERENCE AND 50.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION50.0 VOLTS AC 3RD RADIO INTERFERENCE AND 50.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION
CQJXNOMINAL THREAD SIZE0.190 INCHES
CQRGBODY MATERIALMETAL
ADAQBODY LENGTH5.000 INCHES MAXIMUM
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS0.1 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 5TH RADIO INTERFERENCE 5TH FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION0.5 VOLTS AC 1ST RADIO INTERFERENCE AND 0.05 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION0.5 VOLTS AC 4TH RADIO INTERFERENCE AND 0.05 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION0.5 VOLTS AC 5TH RADIO INTERFERENCE AND 0.1 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION
ABKWOVERALL HEIGHT2.700 INCHES MAXIMUM
ADATBODY WIDTH4.620 INCHES MAXIMUM
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH2.750 INCHES NOMINAL
AFGAOPERATING TEMP RANGE-28.0 TO 85.0 DEG CELSIUS
AFSVAVERAGE LIFE RATING IN HOURS1000.0
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 5TH RADIO INTERFERENCE 5TH FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS0.1 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION0.5 VOLTS AC 2ND RADIO INTERFERENCE AND 0.05 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBPINPUT TERMINAL IDENTIFICATIONBNC-CONNECTOR
AHBTOUTPUT TERMINAL IDENTIFICATIONBNC-RECEPTACLE
AKNAINCLOSURE TYPEHERMETICALLY SEALED
CBBLFEATURES PROVIDEDMOISTURE RESISTANT AND SHOCK RESISTANT
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY2 CONNECTOR,PLUG INPUT 1ST FUNCTION
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY3 CONNECTOR,RECEPTACLE OUTPUT 2ND FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION50.0 VOLTS AC 5TH RADIO INTERFERENCE AND 50.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION
CRSTBODY SURFACE TREATMENTTIN
FEATSPECIAL FEATURESTWENTY-TWO FILTERED FUNCTIONS

Relevant Components for NSN - 5915-01-339-6647, 5915013396647
5930-01-525-6743 (5930015256743) 5905-00-112-5274 (5905001125274) 5962-01-367-6024 (5962013676024) 5975-00-280-9809 (5975002809809)
5962-01-668-1209 (5962016681209) 5995-01-429-6663 (5995014296663) 5945-00-259-0525 (5945002590525) 5999-01-201-4414 (5999012014414)
5985-01-312-4125 (5985013124125) 5962-01-295-0963 (5962012950963) 5935-01-408-8097 (5935014088097) 5998-01-408-9093 (5998014089093)

Submit a Quote and We'll Get Back to You Shortly

Guaranteed quotes back within 15 minutes, 24/7 x 365

Thank You for Visiting.

If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.

Request for Quote

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.

bottom to top