With Satellite To Submarine Parts as your purchasing platform, you can procure NSN 5925-01-228-9058 supplies with the benefit of fair-market pricing, quality assurance, and timely delivery. As you explore the catalog organized on this page, be sure to take note of in-demand part numbers like 126-352, AM3-A8-A-10-0-20, and others that are featured. If any items within our NSN 5925-01-228-9058 inventory are of interest to you or your operations, take advantage of our quotation services for the means of obtaining information on pricing and procurement. You can do this through the submission of an online Request for Quote (RFQ) form or by contacting our staff directly, either of which will allow you to receive fully customized options for your comparisons.
As a website owned and operated by ASAP Semiconductor, those who shop on Satellite To Submarine Parts will be treated to streamlined fulfillment options and dedicated service. Whether you are simply shopping for NSN 5925-01-228-9058 parts for routine operations or pressing maintenance requirements, you can expect our staff to work closely with you to ensure that all needs are met with the utmost care and efficiency. To see why so many steadily depend on us, take the first step of procurement today and get connected with an account manager.
Item Name | Circuit Breaker |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5925 Circuit Breakers |
National Item Identification Number (NIIN) | 01-228-9058 (012289058) |
NCB Code | USA (01) |
Manufacturer | Ampex Data Systems Corporation, Eaton Corporation |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
126-352 | ampex data systems corporation | circuit breaker | 09150 | RFQ |
AM3-A8-A-10-0-20 | eaton corporation | circuit breaker | 74193 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
MRC | Decoded Requirement | Clear Text Reply |
THSD | Thread Series Designator | UNC |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT |
CPLM | Maximum Continuous Load Current Rating Per Pole | 10.0 AMPERES AC ALL LOCATIONS |
PKWT | Unpackaged Unit Weight | 12.000 OUNCES |
AKPX | Pole Quantity | 3 |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 6 THREADED STUD |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CBBL | Features Provided | HIGH INRUSH PROTECTION |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
AJEC | Boss Height | 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM |
CPRQ | Reset Method | MANUAL |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRW | Actuator Function | TRIP-RESET |
ADAT | Body Width | 2.240 INCHES MINIMUM AND 2.251 INCHES MAXIMUM |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 6 THREADED HOLE |
CQJX | Nominal Thread Size | 0.138 INCHES |
ADTV | Case Material | PLASTIC |
AJWX | Mounting Surface To Terminal End Distance | 2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM |
ADAQ | Body Length | 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 3.000 MINIMUM AT 200 PCT AND 11.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRX | Actuator Position Designation | AT EACH POLE |
CMLP | Thread Quantity Per Inch | 32 |
Relevant Components for NSN - 5925-01-228-9058, 5925012289058 | ||||
5998-01-656-8453 (5998016568453) | 5999-01-342-7141 (5999013427141) | 5998-01-543-6815 (5998015436815) | 5935-01-147-5778 (5935011475778) | |
5962-01-459-8232 (5962014598232) | 5935-01-614-6410 (5935016146410) | 5935-01-189-0128 (5935011890128) | 5962-01-216-2450 (5962012162450) | |
5980-01-246-6645 (5980012466645) | 5970-01-662-0429 (5970016620429) | 5950-01-270-0336 (5950012700336) | 5930-01-003-0509 (5930010030509) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote