With Satellite To Submarine Parts as your purchasing platform, you can procure NSN 5950-00-239-7547 supplies with the benefit of fair-market pricing, quality assurance, and timely delivery. As you explore the catalog organized on this page, be sure to take note of in-demand part numbers like 73C828-004, and others that are featured. If any items within our NSN 5950-00-239-7547 inventory are of interest to you or your operations, take advantage of our quotation services for the means of obtaining information on pricing and procurement. You can do this through the submission of an online Request for Quote (RFQ) form or by contacting our staff directly, either of which will allow you to receive fully customized options for your comparisons.
As a website owned and operated by ASAP Semiconductor, those who shop on Satellite To Submarine Parts will be treated to streamlined fulfillment options and dedicated service. Whether you are simply shopping for NSN 5950-00-239-7547 parts for routine operations or pressing maintenance requirements, you can expect our staff to work closely with you to ensure that all needs are met with the utmost care and efficiency. To see why so many steadily depend on us, take the first step of procurement today and get connected with an account manager.
Item Name | Transformer Power |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5950 Coils and Transformers |
National Item Identification Number (NIIN) | 00-239-7547 (002397547) |
NCB Code | USA (00) |
Manufacturer | Ail Systems Inc, Pulse Electronics Corporation, Robert M Hadley Company Inc |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
73C828-004 | ail systems inc | transformer power | 04660 | RFQ |
73C828-004 | pulse electronics corporation | transformer power | 90095 | RFQ |
73C828-004 | robert m hadley company inc | transformer power | 72964 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.552 INCHES MINIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP AND 3.109 INCHES MINIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP AND 1.572 INCHES MAXIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP3.141 INCHES MAXIMUM SINGLE MOUNTING FACILIT |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.109 INCHES MINIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP AND 3.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.109 INCHES MINIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP AND 3.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.990 INCHES MINIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP AND 1.672 INCHES MINIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP AND 1.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP1.704 INCHES MAXIMUM SINGLE MOUNTING FACILIT |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.672 INCHES MINIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP AND 1.704 INCHES MAXIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.672 INCHES MINIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP AND 1.704 INCHES MAXIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP |
ABKW | OVERALL HEIGHT | 1.859 INCHES MINIMUM AND 1.891 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-DELTA |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.859 INCHES MINIMUM AND 3.891 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.172 INCHES MINIMUM AND 2.204 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 170.0 DEG CELSIUS |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.109 INCHES MINIMUM SINGLE MOUNTING FACILITY 1ST CENTER GROUP AND 1.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY 1ST CENTER GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 2 1ST GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 2ND GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 3RD GROUP2 1ST GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 4TH GROUP4 2ND GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE ALL GROUPINGS |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES 2ND GROUP |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES 3RD GROUP0.138 INCHES 1ST GROUP |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES 1ST GROUP |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES 4TH GROUP0.112 INCHES 2ND GROUP |
CRBZ | WINDING OPERATING CURRENT | 40.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 40.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 600.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 84.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 1.6 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY5.46 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 1.8 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY41.52 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 41.52 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 5.46 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 1.038 AC KILOVOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY65.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 3.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY1.038 AC KILOVOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 39.20 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 40.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY8.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 65.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 8.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY39.20 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY |
FEAT | SPECIAL FEATURES | TWO PRIMARY WINDINGS; SIX SECONDARY WINDINGS |
TEST | TEST DATA DOCUMENT | 04660-73C828 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
THSD | THREAD SERIES DESIGNATOR | UNC ALL GROUPINGS |
TTQY | TERMINAL TYPE AND QUANTITY | 25 TURRET |
Relevant Components for NSN - 5950-00-239-7547, 5950002397547 | ||||
5962-01-418-2475 (5962014182475) | 5985-01-368-2899 (5985013682899) | 5930-01-420-7197 (5930014207197) | 5998-00-003-8684 (5998000038684) | |
5961-01-298-2067 (5961012982067) | 5910-00-546-4871 (5910005464871) | 5935-01-361-4308 (5935013614308) | 5975-01-597-5766 (5975015975766) | |
5970-01-242-9099 (5970012429099) | 5995-01-103-1868 (5995011031868) | 5962-00-430-8234 (5962004308234) | 5935-00-480-5119 (5935004805119) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.