Item Name | Power Supply |
Federal Supply Group (FSG) | Electric Wire and Power and Distribution Equipment |
Federal Supply Class (FSC) | 6130 Converters Electrical Non Rotating |
National Item Identification Number (NIIN) | 01-386-7111 (013867111) |
NCB Code | USA (01) |
Manufacturer | Unipower Llc |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
706-1433-000 | unipower llc | power supply | 0rwg8 | RFQ |
EJK2335-046 | unipower llc | power supply | 0rwg8 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AGAV | END ITEM IDENTIFICATION | AN/TPS-72(V)5 |
APNX | INPUT VOLTAGE RATING | 180.0 AC VOLTS MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 264.0 AC VOLTS MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 90.0 AC VOLTS MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 132.0 AC VOLTS MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT |
CWGH | OUTPUT CURRENT RATING | 100.0 DC AMPERES NOMINAL 4TH POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | CONNECTOR,PLUG 2ND POWER OUTPUT AND TERMINAL STRIP 2ND POWER OUTPUT |
CWKG | VENTILATION DESIGN TYPE | SINGLE FAN |
ANPM | INPUT PHASE | SINGLE 1ST ALTERNATE OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 2ND ALTERNATE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 12.0 DC POUNDS PER HOUR WET 3RD POWER OUTPUT |
AYNH | OPERATING AMBIENT TEMP RANGE | 0.1/71.0 DEG CELSIUS |
CBBL | FEATURES PROVIDED | EMI FILTER AND OVER TEMPERATURE PROTECTION AND OVER VOLTAGE PROTECTOR |
CWGH | OUTPUT CURRENT RATING | 10.0 DC AMPERES NOMINAL 2ND POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | CONNECTOR,PLUG 3RD POWER OUTPUT AND TERMINAL STRIP 3RD POWER OUTPUT |
FEAT | SPECIAL FEATURES | MADE FROM CA001-1453,COMPUTER PRODUCTS |
ABHP | OVERALL LENGTH | 13.500 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 5.000 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 8.000 INCHES NOMINAL |
APPA | OUTPUT VOLTAGE RATING | 24.0 DC POUNDS PER HOUR WET 1ST POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 5.0 DC POUNDS PER HOUR WET 4TH POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT |
CWGH | OUTPUT CURRENT RATING | 3.0 DC AMPERES NOMINAL 1ST POWER OUTPUT |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
APPA | OUTPUT VOLTAGE RATING | 12.0 DC POUNDS PER HOUR WET 2ND POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 12.0 DC AMPERES NOMINAL 3RD POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | CONNECTOR,PLUG 1ST POWER OUTPUT AND TERMINAL STRIP 1ST POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | CONNECTOR,PLUG 4TH POWER OUTPUT AND TERMINAL STRIP 4TH POWER OUTPUT |
CWWY | POWER SUPPLY EFFICIENCY LINE | 75.0 |
Relevant Components for NSN - 6130-01-386-7111, 6130013867111 | ||||
6115-01-323-2464 (6115013232464) | 6150-00-489-5982 (6150004895982) | 6150-01-589-6303 (6150015896303) | 6145-01-220-8862 (6145012208862) | |
6145-00-498-7647 (6145004987647) | 6145-00-660-8517 (6145006608517) | 6150-00-554-7591 (6150005547591) | 6145-01-301-7905 (6145013017905) | |
6150-01-237-7756 (6150012377756) | 6150-01-660-7304 (6150016607304) | 6115-01-055-2178 (6115010552178) | 6105-01-108-4734 (6105011084734) | |