Whether you are in search of military and defense parts, aerospace parts, or other similar product solutions, Satellite To Submarine Parts is your one-stop shop. Thank you for your interest in part number 5059, a Ballastran Corp item that is listed alongside the description “Transformer Power” and the NSN 5950001184007. To guarantee a swift procurement process for NSN part number 5059, be sure to request a quote by filling out and submitting the RFQ form below, and one of our experts will offer a customized solution for your comparisons in response.
Note : We Will Not Share Your Information To Any Third Parties.
We list everything with as much relevant information as possible to ensure that customers can swiftly identify and procure the exact products they need. For instance, while part number 5059 is manufactured by Ballastran Corp, it is specifically done so under CAGE Code 97315, a unique identifier assigned to a particular facility by the DLA that supplies to various government or defense agencies. Additionally, using the first digits of the NSN 5950-00-118-4007, one can also determine that this part falls under FSC 5950 Coils and Transformers. Keeping this in mind, initiate the purchasing process today to see why so many customers depend on us for the NSN items they require.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-118-4007 Item Description: TRANSFORMER,POWER | 5950 | 001184007 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
5059 | 6 | 2 | 1 |
MRC | Criteria | Characteristic |
---|---|---|
AKPV | Mounting Facility Quantity | 2 SINGLE GROUP |
TTQY | Terminal Type And Quantity | 9 SOLDER STUD |
CWJS | Winding Operating Voltage | 100.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
CWJS | Winding Operating Voltage | 185.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
CWJS | Winding Operating Voltage | 5.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
ADAU | Body Height | 0.187 INCHES NOMINAL |
AXGY | Mounting Method | UNTHREADED HOLE SINGLE GROUP |
AKNA | Inclosure Type | FULLY INCLOSED |
CRBZ | Winding Operating Current | 20.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | Winding Operating Current | 4.0 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | Winding Operating Current | 3.0 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
ACZC | Input-Output Phase Relationship | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | Winding Shielding Method | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ACZB | Frequency Rating | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ADAQ | Body Length | 0.250 INCHES NOMINAL |
AEJN | Distance Between Mounting Facility Centers | 1.700 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
BPLC | Winding Function And Quantity | 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
CWJS | Winding Operating Voltage | 6.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
ABTB | Mounting Hole Diameter | 0.214 INCHES NOMINAL SINGLE GROUP |
MRC | Decoded Requirement | Clear Text Reply |
ADAT | Body Width | 0.250 INCHES NOMINAL |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.