Whether you are in search of military and defense parts, aerospace parts, or other similar product solutions, Satellite To Submarine Parts is your one-stop shop. Thank you for your interest in part number 6999SP133PC2G, a Drs Power And Control Technologies item that is listed alongside the description “Relay Electromagnetic” and the NSN 5945007381662. To guarantee a swift procurement process for NSN part number 6999SP133PC2G, be sure to request a quote by filling out and submitting the RFQ form below, and one of our experts will offer a customized solution for your comparisons in response.
Note : We Will Not Share Your Information To Any Third Parties.
We list everything with as much relevant information as possible to ensure that customers can swiftly identify and procure the exact products they need. For instance, while part number 6999SP133PC2G is manufactured by Drs Power And Control Technologies, it is specifically done so under CAGE Code 27192, a unique identifier assigned to a particular facility by the DLA that supplies to various government or defense agencies. Additionally, using the first digits of the NSN 5945-00-738-1662, one can also determine that this part falls under FSC 5945 Relays and Solenoids. Keeping this in mind, initiate the purchasing process today to see why so many customers depend on us for the NSN items they require.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-00-738-1662 Item PartTypeName: RELAY,ELECTROMAGNETIC | 5945 | 007381662 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
6999SP133PC2G | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAJD | THREAD CLASS | 2B SECOND MOUNTING FACILITY |
AAJF | THREAD DIRECTION | RIGHT-HAND SECOND MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 3.250 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.750 INCHES NOMINAL SECOND MOUNTING FACILITY |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.199 INCHES NOMINAL FIRST MOUNTING FACILITY |
AEBW | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 0.500 INCHES NOMINAL SECOND MOUNTING FACILITY |
AEBW | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 0.750 INCHES MINIMUM FIRST MOUNTING FACILITY AND 1.500 INCHES MAXIMUM FIRST MOUNTING FACILITY |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APCN | COIL QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE SECOND MOUNTING FACILITY |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE FIRST MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CMLP | THREAD QUANTITY PER INCH | 32 SECOND MOUNTING FACILITY |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SECOND MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SECOND MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CRXH | TIME DELAY | 5.00 SECONDS MINIMUM ADJUSTABLE OPERATE TIME AND 50.00 SECONDS MAXIMUM ADJUSTABLE OPERATE TIME |
CSQC | AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 480.0 AC |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 440.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
CWJB | ENERGIZING ELEMENT POWER RATING | 8.0 WATTS |
THSD | THREAD SERIES DESIGNATOR | UNC SECOND MOUNTING FACILITY |
TTQY | TERMINAL TYPE AND QUANTITY | 14 SCREW ALL FUNCTIONS |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.880 INCHES NOMINAL FIRST MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 4.520 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 3.090 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL |
AKDX | WINDING QUANTITY | 1 |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
CBME | CUBIC MEASURE | 45.392 CUBIC INCHES |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR FIRST MOUNTING FACILITY |
CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 2 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD AND 15.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 240.0 AC AND 30.0 DC |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.