Whether you are in search of military and defense parts, aerospace parts, or other similar product solutions, Satellite To Submarine Parts is your one-stop shop. Thank you for your interest in part number 51-151-01, a Eldec Corporation item that is listed alongside the description “Coil Electrical” and the NSN 5950013264300. To guarantee a swift procurement process for NSN part number 51-151-01, be sure to request a quote by filling out and submitting the RFQ form below, and one of our experts will offer a customized solution for your comparisons in response.
Note : We Will Not Share Your Information To Any Third Parties.
We list everything with as much relevant information as possible to ensure that customers can swiftly identify and procure the exact products they need. For instance, while part number 51-151-01 is manufactured by Eldec Corporation, it is specifically done so under CAGE Code 08748, a unique identifier assigned to a particular facility by the DLA that supplies to various government or defense agencies. Additionally, using the first digits of the NSN 5950-01-326-4300, one can also determine that this part falls under FSC 5950 Coils and Transformers. Keeping this in mind, initiate the purchasing process today to see why so many customers depend on us for the NSN items they require.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-326-4300 Item PartTypeName: COIL,ELECTRICAL | 5950 | 013264300 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
51-151-01 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 5.230 INCHES MINIMUM AND 5.270 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.650 INCHES NOMINAL 1ST MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 1.400 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 3.480 INCHES MINIMUM AND 3.520 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 67.0 DEG CELSIUS |
CRGS | DC RESISTANCE RATING IN OHMS | 0.040 SINGLE COMPONENT ALL WINDING |
CWJS | WINDING OPERATING VOLTAGE | 1.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL WINDING |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.100 INCHES NOMINAL 1ST MOUNTING FACILITY SINGLE CENTER GROUP |
ACYV | INDUCTANCE RATING | 240.00 MICROHENRIES MINIMUM SINGLE COMPONENT ALL WINDING |
ACZR | CORE CONSTRUCTION | S0LID SINGLE COMPONENT |
AKDX | WINDING QUANTITY | 6 SINGLE COMPONENT |
AKPV | MOUNTING FACILITY QUANTITY | 4 1ST GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE 1ST GROUP |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT ALL WINDING |
THSD | THREAD SERIES DESIGNATOR | UNC ALL GROUPINGS |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.850 INCHES NOMINAL 2ND MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.305 INCHES NOMINAL 2ND MOUNTING FACILITY SINGLE CENTER GROUP |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES ALL GROUPINGS |
TEST | TEST DATA DOCUMENT | 08748-TF51-151 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA |
TTQY | TERMINAL TYPE AND QUANTITY | 12 WIRE LEAD |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 2 2ND GROUP |
AXGY | MOUNTING METHOD | THREADED STUD 2ND GROUP |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.