Whether you are in search of military and defense parts, aerospace parts, or other similar product solutions, Satellite To Submarine Parts is your one-stop shop. Thank you for your interest in part number FLUKE 87, a Fluke Uk Ltd item that is listed alongside the description “Multimeter” and the NSN 6625011318586. To guarantee a swift procurement process for NSN part number FLUKE 87, be sure to request a quote by filling out and submitting the RFQ form below, and one of our experts will offer a customized solution for your comparisons in response.
Note : We Will Not Share Your Information To Any Third Parties.
We list everything with as much relevant information as possible to ensure that customers can swiftly identify and procure the exact products they need. For instance, while part number FLUKE 87 is manufactured by Fluke Uk Ltd, it is specifically done so under CAGE Code K6022, a unique identifier assigned to a particular facility by the DLA that supplies to various government or defense agencies. Additionally, using the first digits of the NSN 6625-01-131-8586, one can also determine that this part falls under FSC 6625 Electrical and Electronic Properties Measuring and Testing Instruments. Keeping this in mind, initiate the purchasing process today to see why so many customers depend on us for the NSN items they require.
MRC | Criteria | Characteristic |
---|---|---|
SUPP | Supplementary Features | VISUAL AND AUDIBLE CONTINUITY; PEAK-HOLD; LEVEL DETECTION; CONDUCTANCE; DIODE TEST |
BHMW | Measurement Range | +0.0 TO 750.0 VOLTS, AC SINGLE INDICATOR 14TH RANGE |
AMQY | Installation Design | HAND HELD |
BHMW | Measurement Range | +0.0 TO 2.0 VOLTS, AC SINGLE INDICATOR 12TH RANGE |
BHMW | Measurement Range | +0.0 TO 2000.0 MILLIAMPERES, DC SINGLE INDICATOR 8TH RANGE |
BHMW | Measurement Range | +0.0 TO 200.0 MILLIVOLTS, AC SINGLE INDICATOR 9TH RANGE |
MATT | Material | PLASTIC |
ABMK | Overall Width | 3.400 INCHES NOMINAL |
CBBL | Features Provided | ELECTRICAL OVERLOAD PROTECTION AND INTERNAL BATTERY ACCOMMODATION AND PORTABLE AND WARNING FEATURE |
CTWN | Operating Voltage Rating In Volts | 9.0 DC NOMINAL |
CTTD | Circuit Attachment Method And Quantity | 3 WIRE LEAD |
ZZZV | Fsc Application Data | TEST SET,ELECT. EQUIP. |
CTPT | Accuracy Rating | PORM 0.1 PCT OF READING PLUS 1 DIGIT SINGLE INDICATOR 10TH RANGE |
CTPT | Accuracy Rating | PORM 0.2 PCT OF READING PLUS 3 DIGITS SINGLE INDICATOR 11TH RANGE |
CTPT | Accuracy Rating | PORM 1.5 PCT OF READING PLUS 2 DIGITS SINGLE INDICATOR 6TH RANGE |
CTQH | Display Color | BLACK SINGLE INDICATOR ALL RANGES |
BFQP | Display Digit Quantity | 3/1/2002 |
FEAT | Special Features | CRITICAL APPL-TRANS;RADAR SET,AN/TPS-32; TAC AIR OPN CNTL,AN/TYQ-2 |
BFQN | Display Type | LIQUID CRYSTAL |
BLSB | Scale Selection Method | SWITCH AND TERMINAL |
ABFY | Overall Depth | 1.800 INCHES NOMINAL |
AQFY | Background Color | GRAY SINGLE INDICATOR ALL RANGES |
ABHP | Overall Length | 7.100 INCHES NOMINAL |
AKYN | Furnished Items And Quantity | MANUAL 1; TEST LEAD 2; 9 V BTRY 1; OPER CARD 1; FUSE 1; CAL CERTIFICATE 1 |
ADZC | Environmental Protection | COLD RESISTANT AND HEAT RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT AND WATER RESISTANT |
ANSY | Frequency Response Range | +48.000 TO 450.000 HERTZ |
BHMW | Measurement Range | +0.0 TO 1000.0 VOLTS, DC SINGLE INDICATOR 16TH RANGE |
BHMW | Measurement Range | +0.0 TO 200.0 MILLIVOLTS, DC SINGLE INDICATOR 10TH RANGE |
BHMW | Measurement Range | +0.0 TO 2.0 VOLTS, DC SINGLE INDICATOR 15TH RANGE |
BHMW | Measurement Range | +0.0 TO 2.0 MILLIAMPERES, DC SINGLE INDICATOR 7TH RANGE |
BHMW | Measurement Range | +0.0 TO 2000.0 MILLIAMPERES, AC SINGLE INDICATOR 6TH RANGE |
BHMW | Measurement Range | +0.0 TO 200.0 OHMS SINGLE INDICATOR 11TH RANGE |
STYL | Style Designator | HAND-HELD |
NHCF | Nuclear Hardness Critical Feature | NONHARDENED |
BHMW | Measurement Range | +0.0 TO 2.0 KILOHMS SINGLE INDICATOR 1ST RANGE |
BHMW | Measurement Range | +0.0 TO 200.0 VOLTS, AC SINGLE INDICATOR 13TH RANGE |
BHMW | Measurement Range | +0.0 TO 20.0 MILLIAMPERES, AC SINGLE INDICATOR 5TH RANGE |
BHMW | Measurement Range | +0.0 TO 2.0 MILLIAMPERES, AC SINGLE INDICATOR 4TH RANGE |
BHMW | Measurement Range | +0.0 TO 2000.0 KILOHMS SINGLE INDICATOR 2ND RANGE |
BHMW | Measurement Range | +0.0 TO 20.0 MEGOHMS SINGLE INDICATOR 3RD RANGE |
AACT | Circuit Current For Which Designed | DC |
MRC | Decoded Requirement | Clear Text Reply |
AMKD | Indicator Type | DIGITAL DISPLAY |
AWZJ | Power Source | INTERNAL |
CTPT | Accuracy Rating | PORM 0.1 PCT OF READING PLUS 1 DIGIT SINGLE INDICATOR 16TH RANGE |
CTPT | Accuracy Rating | PORM 0.75 PCT OF READING PLUS 1 DIGIT SINGLE INDICATOR 8TH RANGE |
CTPT | Accuracy Rating | PORM 0.1 PCT OF READING PLUS 1 DIGIT SINGLE INDICATOR 1ST RANGE |
CTPT | Accuracy Rating | PORM 1.0 PCT OF READING PLUS 2 DIGITS SINGLE INDICATOR 14TH RANGE |
CTPT | Accuracy Rating | PORM 2.0 PCT OF READING PLUS 1 DIGIT SINGLE INDICATOR 3RD RANGE |
CTPT | Accuracy Rating | PORM 3.0 PCT OF READING PLUS 2 DIGITS SINGLE INDICATOR 4TH RANGE |
CTPT | Accuracy Rating | POAM 5.0 PCT OF READING PLUS 5 DIGITS SINGLE INDICATOR 9TH RANGE |
CTPT | Accuracy Rating | PORM 0.1 PCT OF READING PLUS 1 DIGIT SINGLE INDICATOR 15TH RANGE |
CTPT | Accuracy Rating | PORM 0.75 PCT OF READING PLUS 1 DIGIT SINGLE INDICATOR 7TH RANGE |
CTPT | Accuracy Rating | PORM 0.15 PCT OF READING PLUS 1 DIGIT SINGLE INDICATOR 2ND RANGE |
CTPT | Accuracy Rating | PORM 1.5 PCT OF READING PLUS 3 DIGITS SINGLE INDICATOR 13TH RANGE |
CTPT | Accuracy Rating | PORM 1.5 PCT OF READING PLUS 2 DIGITS SINGLE INDICATOR 5TH RANGE |
CTPT | Accuracy Rating | PORM 5.0 PCT OF READING PLUS 5 DIGITS SINGLE INDICATOR 12TH RANGE |
CRTL | Criticality Code Justification | FEAT |