Whether you are in search of military and defense parts, aerospace parts, or other similar product solutions, Satellite To Submarine Parts is your one-stop shop. Thank you for your interest in part number 50296, a Gems Sensors Inc item that is listed alongside the description “Switch Liquid Level” and the NSN 5930010836316. To guarantee a swift procurement process for NSN part number 50296, be sure to request a quote by filling out and submitting the RFQ form below, and one of our experts will offer a customized solution for your comparisons in response.
Note : We Will Not Share Your Information To Any Third Parties.
We list everything with as much relevant information as possible to ensure that customers can swiftly identify and procure the exact products they need. For instance, while part number 50296 is manufactured by Gems Sensors Inc, it is specifically done so under CAGE Code 04034, a unique identifier assigned to a particular facility by the DLA that supplies to various government or defense agencies. Additionally, using the first digits of the NSN 5930-01-083-6316, one can also determine that this part falls under FSC 5930 Switches. Keeping this in mind, initiate the purchasing process today to see why so many customers depend on us for the NSN items they require.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-01-083-6316 Item PartTypeName: SWITCH,LIQUID LEVEL | 5930 | 010836316 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
10308 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 8.500 INCHES NOMINAL |
ACYN | AC VOLTAGE RATING | 120.0 VOLTS MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT |
ACYN | AC VOLTAGE RATING | 240.0 VOLTS MAXIMUM 3RD ALTERNATE OPERATING POWER RQMT |
ACYN | AC VOLTAGE RATING | 50.0 VOLTS MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT |
ACYR | DC VOLTAGE RATING | 120.0 VOLTS MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT |
ACYR | DC VOLTAGE RATING | 240.0 VOLTS MAXIMUM 3RD ALTERNATE OPERATING POWER RQMT |
ACYR | DC VOLTAGE RATING | 50.0 VOLTS MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL 3RD ALTERNATE OPERATING POWER RQMT |
ADAV | OVERALL DIAMETER | 6.125 INCHES NOMINAL |
AEEE | CONNECTOR MANUFACTURER CODE | 92219 |
AFLW | ACTUATION METHOD | BUOYANCY |
AGBD | ELECTRICAL CONNECTION TYPE | TERMINAL LUG |
AGBG | CONNECTOR IDENTIFICATION | 19192 |
ALSF | INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED 1ST ALTERNATE OPERATING POWER RQMT |
ALSF | INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED 2ND ALTERNATE OPERATING POWER RQMT |
ALSF | INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED 3RD ALTERNATE OPERATING POWER RQMT |
APGW | CURRENT RATING AT MAXIMUM RATED VOLTAGE | 0.06 AMPERES RESISTIVE LOAD |
APGY | VOLTAGE RATING AT MAXIMUM RATED CURRENT | 120.0 VOLTS |
AWAE | FLOAT QUANTITY | 1 |
AWTN | OPERATING TEMP RATING | 65.0 DEG FAHRENHEIT MINIMUM AND 250.0 DEG FAHRENHEIT MAXIMUM |
AXGY | MOUNTING METHOD | FLANGE |
BBJX | MOUNTING POSITION | VERTICAL |
BJKC | MAXIMUM CURRENT RATING | 0.12 AMPERES RESISTIVE LOAD |
BJKD | CONTACT ARRANGEMENT | SPST NORMALLY OPEN |
BJKG | RELAY | NOT INCLUDED |
BJKH | LIQUID TYPE FOR WHICH DESIGNED | HYDRAULIC OIL AND LUBRICATING OIL AND SEA WATER AND VARIOUS FUELS |
BJKN | FLOAT EFFECTIVE TRAVEL | 2.500 INCHES NOMINAL |
BJKP | MOUNTING DIMENSIONS | SIX 0.562 IN. DIA HOLES EQUALLY SPACED ON A 5.000 IN. DIA BOLT CIRCLE |
BJKQ | TANK INSERTION LENGTH | 5.000 INCHES NOMINAL |
FAAZ | PHASE | SINGLE 1ST ALTERNATE OPERATING POWER RQMT |
FAAZ | PHASE | SINGLE 2ND ALTERNATE OPERATING POWER RQMT |
FAAZ | PHASE | SINGLE 3RD ALTERNATE OPERATING POWER RQMT |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote