Whether you are in search of military and defense parts, aerospace parts, or other similar product solutions, Satellite To Submarine Parts is your one-stop shop. Thank you for your interest in part number 2392333G2, a Harris Corporation item that is listed alongside the description “Filter Radio Frequency Interfere” and the NSN 5915009252513. To guarantee a swift procurement process for NSN part number 2392333G2, be sure to request a quote by filling out and submitting the RFQ form below, and one of our experts will offer a customized solution for your comparisons in response.
Note : We Will Not Share Your Information To Any Third Parties.
We list everything with as much relevant information as possible to ensure that customers can swiftly identify and procure the exact products they need. For instance, while part number 2392333G2 is manufactured by Harris Corporation, it is specifically done so under CAGE Code 28527, a unique identifier assigned to a particular facility by the DLA that supplies to various government or defense agencies. Additionally, using the first digits of the NSN 5915-00-925-2513, one can also determine that this part falls under FSC 5915 Filters and Networks. Keeping this in mind, initiate the purchasing process today to see why so many customers depend on us for the NSN items they require.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-00-925-2513 Item Description: FILTER,RADIO FREQUENCY INTERFERE | 5915 | 009252513 | Y | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
Z3 | ||||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
2392333G2 | C | 2 | 5 | Z3 | BFWRN |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 5.375 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.375 INCHES NOMINAL |
ADAT | BODY WIDTH | 1.031 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.000 INCHES NOMINAL |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 4TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.6 1ST RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.6 2ND RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.6 3RD RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.6 4TH RADIO INTERFERENCE |
AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED STUD |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG OUTPUT 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION AND 28.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION AND 28.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION AND 28.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION AND 28.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
CQRG | BODY MATERIAL | METAL |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.