Whether you are in search of military and defense parts, aerospace parts, or other similar product solutions, Satellite To Submarine Parts is your one-stop shop. Thank you for your interest in part number 311-14834-01, a Oeco Llc item that is listed alongside the description “Transformer Power” and the NSN 5950013313922. To guarantee a swift procurement process for NSN part number 311-14834-01, be sure to request a quote by filling out and submitting the RFQ form below, and one of our experts will offer a customized solution for your comparisons in response.
Note : We Will Not Share Your Information To Any Third Parties.
We list everything with as much relevant information as possible to ensure that customers can swiftly identify and procure the exact products they need. For instance, while part number 311-14834-01 is manufactured by Oeco Llc, it is specifically done so under CAGE Code 95266, a unique identifier assigned to a particular facility by the DLA that supplies to various government or defense agencies. Additionally, using the first digits of the NSN 5950-01-331-3922, one can also determine that this part falls under FSC 5950 Coils and Transformers. Keeping this in mind, initiate the purchasing process today to see why so many customers depend on us for the NSN items they require.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-331-3922 Item PartTypeName: TRANSFORMER,POWER | 5950 | 013313922 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
311-14834-01 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.990 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.990 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 2.270 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.181 INCHES MINIMUM SINGLE GROUP AND 0.201 INCHES MAXIMUM SINGLE GROUP |
CRMJ | WINDING POWER RATING | 7.42 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 14.85 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
TEST | TEST DATA DOCUMENT | 13973-841355 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 4.560 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 3.850 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 45.0 HERTZ MINIMUM SINGLE COMPONENT AND 66.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.75 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 500.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 16.6 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 9.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 208.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 10 TAB,SOLDER LUG |