Whether you are in search of military and defense parts, aerospace parts, or other similar product solutions, Satellite To Submarine Parts is your one-stop shop. Thank you for your interest in part number 533257-112, a Raytheon Company item that is listed alongside the description “Circuitbreaker” and the NSN 5925004767997. To guarantee a swift procurement process for NSN part number 533257-112, be sure to request a quote by filling out and submitting the RFQ form below, and one of our experts will offer a customized solution for your comparisons in response.
Note : We Will Not Share Your Information To Any Third Parties.
We list everything with as much relevant information as possible to ensure that customers can swiftly identify and procure the exact products they need. For instance, while part number 533257-112 is manufactured by Raytheon Company, it is specifically done so under CAGE Code 96214, a unique identifier assigned to a particular facility by the DLA that supplies to various government or defense agencies. Additionally, using the first digits of the NSN 5925-00-476-7997, one can also determine that this part falls under FSC 5925 Circuit Breakers. Keeping this in mind, initiate the purchasing process today to see why so many customers depend on us for the NSN items they require.
MRC | Criteria | Characteristic |
---|---|---|
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.594 INCHES MINIMUM AND |
CQXF | Inclosure Protection Type For Which Designed | HERMETICALLY SEALED AND |
BBRJ | Special Handling Feature | MAGNETIC |
MRC | Decoded Requirement | Clear Text Reply |
CQXF | Inclosure Protection Type For Which Designed | SHOCK RESISTANT AND |
CPLM | Maximum Continuous Load Current Rating Per Pole | 3.0 AMPERES AC ALL LOCATIONS |
AKPX | Pole Quantity | 3 |
AEFP | Nonturn Device Radius | 0.656 INCHES MAXIMUM |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
TTQY | Terminal Type And Quantity | 6 WIRE HOOK |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
AEFP | Nonturn Device Radius | 0.594 INCHES MINIMUM AND |
AEFQ | Nonturn Device Length | 0.063 INCHES MINIMUM AND |
AEFS | Nonturn Device Diameter | 0.171 INCHES MAXIMUM |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 150.0 ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRX | Actuator Position Designation | AT POLE TWO |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
ADTV | Case Material | METAL |
CPRW | Actuator Function | TRIP-RESET |
AAJE | Thread Pitch Diameters | 0.3503 TO 0.3537 INCHES |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING W/PANEL SEAL |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
AJWX | Mounting Surface To Terminal End Distance | 1.780 INCHES MAXIMUM |
AEFN | Nonturn Device Location | AT 3 OCLOCK AND |
AEFN | Nonturn Device Location | AT 9 OCLOCK |
AEFQ | Nonturn Device Length | 0.125 INCHES MAXIMUM |
AEFS | Nonturn Device Diameter | 0.109 INCHES MINIMUM AND |
ADAQ | Body Length | 1.500 INCHES MAXIMUM |
CQJX | Nominal Thread Size | 0.375 INCHES |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.906 INCHES MAXIMUM |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.656 INCHES MAXIMUM |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.844 INCHES MINIMUM AND |
ABXD | Bushing Length | 0.380 INCHES MAXIMUM |
ADAT | Body Width | 1.875 INCHES MAXIMUM |
CMLP | Thread Quantity Per Inch | 32 |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.900 MINIMUM AT 200 PCT AND |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 4.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
THSD | Thread Series Designator | UNEF |
CQXF | Inclosure Protection Type For Which Designed | VIBRATION RESISTANT |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.