Whether you are in search of military and defense parts, aerospace parts, or other similar product solutions, Satellite To Submarine Parts is your one-stop shop. Thank you for your interest in part number 8914319-318, a Rca Corp item that is listed alongside the description “Capacitor Fixed Mica Dielectric” and the NSN 5910005773170. To guarantee a swift procurement process for NSN part number 8914319-318, be sure to request a quote by filling out and submitting the RFQ form below, and one of our experts will offer a customized solution for your comparisons in response.
Note : We Will Not Share Your Information To Any Third Parties.
We list everything with as much relevant information as possible to ensure that customers can swiftly identify and procure the exact products they need. For instance, while part number 8914319-318 is manufactured by Rca Corp, it is specifically done so under CAGE Code 21921, a unique identifier assigned to a particular facility by the DLA that supplies to various government or defense agencies. Additionally, using the first digits of the NSN 5910-00-577-3170, one can also determine that this part falls under FSC 5910 Capacitors. Keeping this in mind, initiate the purchasing process today to see why so many customers depend on us for the NSN items they require.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5910-00-577-3170 Item Description: Capacitor Fixed Mica Dielectric | 5910 | 005773170 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
8914319-318 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ADAT | BODY WIDTH | 0.375 INCHES NOMINAL |
AAQL | BODY STYLE | W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE |
CRTP | TOLERANCE RANGE PER SECTION | -5.00 TO 5.00 PERCENT SINGLE SECTION |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CRDN | TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUS | -20.0 TO 100.0 SINGLE SECTION |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
CWSG | TERMINAL SURFACE TREATMENT | SOLDER |
ADAQ | BODY LENGTH | 0.453 INCHES NOMINAL |
ABJT | TERMINAL LENGTH | 1.000 INCHES MINIMUM |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 500.0 DC SINGLE SECTION |
CQBQ | CAPACITANCE VALUE PER SECTION | 56.000 PICOFARADS SINGLE SECTION |
CWJK | CASE MATERIAL | PLASTIC |
ADAU | BODY HEIGHT | 0.203 INCHES NOMINAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.225 INCHES NOMINAL |
CWPK | INSULATION RESISTANCE AT REFERENCE TEMP | 100000.0 MEGOHMS |