Whether you are in search of military and defense parts, aerospace parts, or other similar product solutions, Satellite To Submarine Parts is your one-stop shop. Thank you for your interest in part number APS-064, a United Transformer Corp item that is listed alongside the description “Transformerpower” and the NSN 5950004954663. To guarantee a swift procurement process for NSN part number APS-064, be sure to request a quote by filling out and submitting the RFQ form below, and one of our experts will offer a customized solution for your comparisons in response.
Note : We Will Not Share Your Information To Any Third Parties.
We list everything with as much relevant information as possible to ensure that customers can swiftly identify and procure the exact products they need. For instance, while part number APS-064 is manufactured by United Transformer Corp, it is specifically done so under CAGE Code 80223, a unique identifier assigned to a particular facility by the DLA that supplies to various government or defense agencies. Additionally, using the first digits of the NSN 5950-00-495-4663, one can also determine that this part falls under FSC 5950 Coils and Transformers. Keeping this in mind, initiate the purchasing process today to see why so many customers depend on us for the NSN items they require.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-495-4663 Item PartTypeName: TRANSFORMER,POWER | 5950 | 004954663 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
890827 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.060 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.060 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.060 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENTTHREE PHASE TO THREE PHASE SINGLE COMPONENTTHREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 4.250 INCHES NOMINAL4.250 INCHES NOMINAL4.250 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.950 INCHES NOMINAL2.950 INCHES NOMINAL2.950 INCHES NOMINAL |
ADAU | BODY HEIGHT | 2.370 INCHES NOMINAL2.370 INCHES NOMINAL2.370 INCHES NOMINAL |
AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS |
AGAV | END ITEM IDENTIFICATION | WSD: AIRCRAFT,PHANTOM F-4 |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUPTHREADED HOLE SINGLE GROUPTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 8 SECONDARY SINGLE COMPONENT8 SECONDARY SINGLE COMPONENT8 SECONDARY SINGLE COMPONENT |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP32 SINGLE GROUP32 SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP0.164 INCHES SINGLE GROUP0.164 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.1 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 178.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 189.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 310.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 22.0 WATTS SINGLE COMPONENT SINGLE PRIMARY |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CWJS | WINDING OPERATING VOLTAGE | 17.90 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY188.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY17.90 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 31.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 31.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY17.90 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY31.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 46.90 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 46.90 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY17.90 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY46.90 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
FEAT | SPECIAL FEATURES | 5TH SECONDARY 10.5V 118 MA,6TH SEC 10.5V 275 MA,7TH SEC 71.0V 1.5A,8TH SEC 77.5V 1.68A; WEAPON SYSTEM ESSENTIAL |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 27 PIN |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.